DTR
DTR
Industrial
Residential
Sewage drainage pumps. The grinder system allows the pumping of wastewater with suspended solids and prevents blockage of the pump. Ideal for emptying septic tanks and residential sumps, rainwater systems and for draining flooded areas where uninterrupted operation is required.
CONSTRUCTION FEATURES | |
---|---|
Pump body | cast iron |
Impeller | cast iron |
Seal | double seal with oil barrier: pump side silicon carbide, engine side sealing ring |
Pump shaft end | steel AISI 304 |
Ambient temperature | 0 - 40 °C |
G | eraser NBR |
Gaskets | stainless steel A2 |
Bolts | galvanized iron |
STAINER | 20 m |
Motor | |
---|---|
2 poles induction motor in oil bath |
3~ 400V-50Hz 3~ 230/400V-50Hz 3~ 400/690V-50Hz 1~ 230V-50Hz running capacitor (35μF for the models 1,5HP, 50μF for the models da 2HP) + starting capacitor (80μF with circuit breaker) richiesto |
Insulation class | F |
Protection degree | IPX8 |
Motor | |
---|---|
2 poles induction motor in oil bath |
3~ 220/380V-60Hz 1~ 220V-60Hz |
Insulation class | F |
Protection degree | IP68 |
MODEL 1~ | MODEL 3~ | HP | kW | FLOW RATE (l/min) |
H (m) |
PIPE-DNM |
---|---|---|---|---|---|---|
DTR 150 | DTRT 150 | 1.5 | 1.1 | 50 ÷ 300 | 18.5 ÷ 9.9 | 2" G | DTR 200 | DTRT 200 | 2 | 1.5 | 50 ÷ 300 | 21.3 ÷ 13.4 | 2" G |
MODEL 1~ | MODEL 3~ | HP | kW | FLOW RATE (l/min) |
H (m) |
PIPE-DNM |
---|---|---|---|---|---|---|
DTR 200 | DTRT 200 | 2 | 1.5 | 50 ÷ 300 | 21.7 ÷ 12.1 | 2" G | DTR 150 | DTRT 150 | 1.5 | 1.1 | 50 ÷ 300 | 18 ÷ 8.4 | 2" G |