FTR

FTR

Industrial
Residential

Sewage drainage pumps. The grinder system allows the pumping of wastewater with suspended solids and prevents blockage of the pump. Ideal for emptying septic tanks and residential sumps, rainwater systems and for draining flooded areas where uninterrupted operation is required.

CONSTRUCTION FEATURES
Pump body cast iron
Impeller cast iron
Mechanical seal double seal with oil barrier; silicon carbide on pump side, sealing ring on motor side
Motor shaft stainless steel AISI 304
Liquid temperature 0 - 40 °C
Gaskets NBR rubber
Bolts A2 stainless steel
Foot support galvanized iron
Max Depth of immersion 20 mt
Motor
2 poles induction motor in oil bath 3~ 230V-50Hz
3~ 400V-50Hz
3~ 230/400V-50Hz
3~ 400/690V-50Hz
1~ 230V-50Hz
run capacitor (35μF for 1,5HP models, 50μF for 2HP model) + start capacitor (80μF with disjuntor) required
Insulation class F
Protection degree IPX8
MODEL 1~ MODEL 3~ HP kW FLOW RATE
(l/min)
H
(m)
PIPE-DNM
FTR 150 FTR 150 T 1.5 1.1 50 ÷ 300 18.5 ÷ 9.9 2" G
FTR 200 FTR 200 T 2 1.5 50 ÷ 300 21.3 ÷ 13.4 2" G
MODEL 1~ MODEL 3~ HP kW FLOW RATE
(l/min)
H
(m)
PIPE-DNM
FTR 150 FTRT 150 1.5 1.1 50 ÷ 300 18 ÷ 8.4 2" G
FTR 200 FTRT 200 2 1.5 50 ÷ 300 21.7 ÷ 12.1 2" G